LCD Weighing Terminal 5024G

Fully digital OIML certified weighing terminal type 5024G. With alibi memory and software for standard weighing applications. Digital signal processor for displaying and processing the data from the Eilersen range of digital load cells. Durable capacitive touch keyboard.

 

Type: 5024G

 

Options:

  • OEM version
  • Panel mounting
  • Customized application software
  • Mounted in stainless steel housing

Special features:

  • 5,2" LCD for displaying data and parameters
  • Touch keyboard with 7 keys for zeroing, tare function, entering parameters, set-points, etc.
  • Alibi memory
  • Made in Denmark
  • Ethernet, RS485, and 4-20mA ACTIVE output for communication with PCs, PLCs, central data processing systems, printers, bar code readers, etc.
  • 4 configurable 24Vdc I/O
  • Function keys for Start/Stop and Print for handling various processes
  • Durable front with no keyboard to be worn out
  • Optional Profibus DP, DeviceNet, EtherCAT, and ProfiNet (pending) interfaces

Applications:

  • Filling & Dispensing of liquid or bulk material
  • Dosing of liquid or bulk material
  • Mobile weighing
  • Checkweighing
  • Scales
  • Force measurement
  • Level-by-weight
  • Vessel weighing
  • Customer specific application software

Click here for examples of the 5024G Digital LCD Weighing Terminal

 

ProfibusEtherNet IP DeviceNet  OIML   CE

 

Gepubliceerd in Weegterminals
dinsdag, 14 oktober 2014 00:00

ATEX Certified Power Supply 4051A

ATEX certified (zone 1, 2, 21, 22) power supply type 4051A. Used for supplying 4XXXA interface modules when used in ATEX rated applications. The 4051A power supply and 4XXXA interface module must be installed in safe area i.e. outside the ATEX zone. 

 

Type: 4051A

Interface: ATEX power supply

 

Special features:

  • ATEX certified power supply for Eilersen digital weighing modules type 4XXXA
  • Made in Denmark
  • For hazardous applications in ATEX Zone 1, 2, 21 or 22
  • The power supply type 4051A and module type 4XXA must be installed outside the hazardous zone
  • Small Form Factor
  • Output: Safe 24 Vdc, 0.2A output
  • Input: Standard power supply 24 Vdc, 1A

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • OEM version

atex ex   CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

Terminal Module MCE9601

Connection between Eilersen RS485 load cell bus at one side and 24Vdc Power Supply and Eilersen digital weighing terminals on the other side.

 

Type: MCE9601

Interface: 24Vdc supply and Eilersen RS485 load cell bus

 

Special features:

  • Connection between Eilersen Electric Digital Load Cell bus at one side and 24 VDC Power Supply and Eilersen digital weighing terminals on the other side
  • Made in Denmark

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • OEM version

CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

ATEX EtherNet/IP Interf. Mod. 4X50A

ATEX certified (zone 1, 2, 21, 22) EtherNet/IP interface module. For directly interfacing up to four digital ATEX load cells via EtherNet/IP. The interface module type 4X50A can also be used in non-ATEX installations. 

 

Type: 4X50A

Interface: EtherNet/IP

 

Special features:

  • EtherNet/IP output
  • Made in Denmark
  • Weighing module for up to 4 digital load cells
  • For ATEX and non-ATEX applications
  • Plug-and-play installation with Eilersen digital load cells
  • Advanced digital filters (configurable)
  • A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
  • Small Form Factor
  • Setup via dip switches
  • For ATEX when supplied by power supply type 4051A
  • Application software can be made by request
  • The power supply 4051A and module type 4X50A must be installed outside the hazardous zone

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • Customized application software
  • OEM version

  atex ex   CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

EtherNet/IP Interface Module 2050

EtherNet interface module. For interfacing up to eight digital non-ATEX load cells via EtherNet/IP.

 

Type: 2050

Interface: EtherNet/IP

 

Special features:

  • EtherNet/IP communication module for interfacing Eilersen digital load cells to PCs, PLCs and other equipment
  • Made in Denmark
  • The module can be used for up to 8 digital load cells and transmits the weight and status for each individual load cell
  • The module offers plug-and-play installation with Eilersen pre-calibrated digital load cells
  • The module is supplied with an EDS file for easy installation
  • Application software can be made by request

Options:

  • Customized application software
  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • OEM version

Module for interfacing up to eight digital non-ATEX load cells via EtherNet/IP      CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

Serial Interface Module 4140OEM

RS485 interface module for interfacing digital load cells to PLCs, PCs etc. The module is developed for OEM use and can be equipped with customized protocols. 

 

Type: 4140OEM

Interface: RS485

 

Special features:

  • RS485 output
  • Made in Denmark
  • Weighing module with connector for 1 digital load cell
  • Plug-and-play installation with pre-calibrated digital load cell
  • Advanced digital filters (configurable)
  • Setup via dip switches
  • Input: Coaxial connector for 1 digital load cell and power supply 24Vdc, 1A
  • Output: RS485 (Customized protocols available)
  • Application software can be made by request

Options:

  • Prepared for panel mounting on DIN rail
  • Customized application software
  • Mounted in stainless steel housing
  • OEM version

CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

ATEX Serial Interface Module 4X40A

ATEX certified (zone 1, 2, 21, 22) RS485 interface module. For directly interfacing up to four digital ATEX load cells via RS485. The interface module type 4X40A can also be used in non-ATEX installations. 

 

Type: 4X40A

Interface: RS485

 

Special features:

  • RS485 output
  • Made in Denmark
  • Weighing module for up to 4 digital load cells
  • For ATEX and non-ATEX applications
  • Plug-and-play installation with Eilersen digital load cells
  • Advanced digital filters (configurable)
  • Small Form Factor
  • A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
  • Setup via dip switches
  • Application software can be made by request
  • For ATEX when supplied by power supply type 4051A
  • The power supply 4051A and module type 4X40A must be installed outside the hazardous zone

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • Customized application software
  • OEM version

ATEX gecertificeerde weegmodule     CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

Serial Interface Module MCE2040

Serial interface module. For interfacing up to eight digital non-ATEX load cells via RS232, RS485 or RS422 (Optional Modbus ASCII/RTU protocol). 

 

Type: MCE2040

Interface: RS232/RS422/485 (Modbus ASCII/RTU)

 

Special features:

  • Serial RS232/RS485/RS422 communication module for interfacing Eilersen digital load cells to PCs, PLCs and other equipment
  • Made in Denmark
  • The module can be used for up to 8 digital load cells and transmits the weight and status for each individual load cell
  • The module offers plug-and-play installation with Eilersen pre-calibrated digital load cells
  • Optional Modbus ASCII/RTU protocol
  • Application software can be made by request

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • Customized application software
  • OEM version

CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

ATEX DeviceNet Interface 4X37A

ATEX certified (zone 1, 2, 21, 22) DeviceNet interface module. For directly interfacing up to four digital ATEX load cells via DeviceNet. The interface module type 4X37A can also be used in non-ATEX installations. 

 

Type: 4X37A

Interface: DeviceNet

 

Special features:

  • DeviceNet output
  • Made in Denmark
  • Weighing module for up to 4 digital load cells
  • For ATEX and non-ATEX applications
  • Plug-and-play installation with Eilersen digital load cells
  • Advanced digital filters (configurable)
  • A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
  • Setup via dip switches
  • Small Form Factor
  • For ATEX when supplied by power supply type 4051A
  • The power supply 4051A and module type 4X37A must be installed outside the hazardous zone
  • Application software can be made by request

Options:

  • Prepared for panel mounting on DIN rail
  • Mounted in stainless steel housing
  • Customized application software
  • OEM version

DeviceNet  atex ex    CE

Gepubliceerd in Weegmodules
dinsdag, 14 oktober 2014 00:00

DeviceNet Interface Mod. MCE9637

ODVA approved DeviceNet interface module. For interfacing up to eight digital non-ATEX load cells via DeviceNet.

 

Type: MCE9637

Interface: DeviceNet

 

Special features:

  • DeviceNet communication module for interfacing Eilersen digital load cells to a DeviceNet Master device (PLC)
  • Made in Denmark
  • The module can be used for up to 8 digital load cells and transmits the weight and status for each individual load cell
  • Application software can be made by request
  • The module offers plug-and-play installation with Eilersen pre-calibrated digital load cells and the module is supplied with an EDS file for easy installation

Options:

  • Mounted in stainless steel housing
  • Prepared for panel mounting on DIN rail
  • Customized application software
  • OEM version

Module for interfacing up to eight digital non-ATEX load cells via DeviceNet       CE