Toon items op tag: EtherNet
ATEX Modbus TCP/IP Interface 4x50A
ATEX certified (zone 1, 2, 21, 22) Modbus TCP/IP interface module for directly interfacing up to four digital ATEX load cells. The interface module type 4X50A can also be used in non-ATEX installations.
Type: 4X50A
Interface: Modbus TCP/IP
Special features:
- Modbus TCP/IP fieldbus interface
- For ATEX and non-ATEX applications
- Weighing module for up to 4 digital load cells
- Plug-and-play installation with Eilersen digital load cells
- Advanced digital filters (configurable)
- A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
- Small Form Factor
- Setup via dip switches
- For ATEX when supplied by power supply type 4051A
- The power supply 4051A and module type 4X50A must be installed outside the hazardous zone
- Application software can be made by request
- Made in Denmark
Options:
- OEM version
- Customized application software
- Mounted in stainless steel housing
- Prepared for panel mounting on DIN rail
ATEX EtherCAT Interface Mod. 4X60A
ATEX certified (zone 1, 2, 21, 22) EtherCAT interface module for directly interfacing up to four digital ATEX load cells via EtherCAT. The interface module type 4X60A can also be used in non-ATEX installations.
Type: 4X60A
Interface: EtherCAT
Special features:
- EtherCAT interface
- Weighing module for up to 4 digital load cells
- For ATEX and non-ATEX applications
- Plug-and-play installation with Eilersen digital load cells
- Advanced digital filters (configurable)
- A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
- Setup via dip switches
- Small Form Factor
- For ATEX installation when supplied by power supply type 4051A
- The power supply 4051A and module type 4X60A must be installed outside the hazardous zone
- Application software can be made by request
- Made in Denmark
Options:
- OEM version
- Customized application software
- Mounted in stainless steel housing
- Prepared for panel mounting on DIN rail
Analog Output Module 4X79A
Analog output weighing module featuring a LED display, 4-20mA or 0-10Vdc active analog output and digital EtherNet interface. The module also features four I/O for level alarms and remote zeroing. This module can directly connect to up to four digital load cells.
Type: 4X79A
Interface: Analog output (4-20mA or 0-10Vdc active output) and Ethernet interface
Special features:
- Analog 4-20mA or 0-10Vdc ACTIVE output
- Digital EtherNet interface
- Six character LED display
- 2 digital inputs + 2 digital outputs
- Weighing module for up to 4 digital load cells
- Can show the weight on the connected load cells
- Can show the summed weight for the connected load cells
- Configurable measuring time (20ms -> 4sec)
- 16bit D/A converter
- Setup via dip switches
- For ATEX when supplied by power supply type 4051A
- The power supply 4051A and module type 4X70A must be installed outside the hazardous zone
- Plug-and-play installation with Eilersen digital load cells
- Input for zeroing
- A "Digital Junction Box" that can be mounted near the load cells or in a central panel
- Application specific software can be made by request
- Made in Denmark
Options:
- Customized application software
- Mounted in stainless steel housing
- Prepared for panel mounting on DIN rail
PROFINET Interface Module 2070
PROFINET interface module for interfacing up to eight digital non-ATEX load cells via PROFINET fieldbus interface.
Type: 2070
Interface: PROFINET
Special features:
- PROFINET communication module for interfacing Eilersen digital load cells to PCs, PLCs and other equipment
- The module can be used for up to 8 digital load cells and transmits the weight and status for each individual load cell
- The module offers plug-and-play installation with Eilersen pre-calibrated digital load cells
- The module is supplied with an GSD XML file for easy installation
- Application software can be made by request
- Made in Denmark
Options:
- Prepared for panel mounting on DIN rail
- Customized application software
- Mounted in stainless steel housing
- OEM version
ATEX EtherNet/IP Interf. Mod. 4X50A
ATEX certified (zone 1, 2, 21, 22) EtherNet/IP interface module. For directly interfacing up to four digital ATEX load cells via EtherNet/IP. The interface module type 4X50A can also be used in non-ATEX installations.
Type: 4X50A
Interface: EtherNet/IP
Special features:
- EtherNet/IP output
- Made in Denmark
- Weighing module for up to 4 digital load cells
- For ATEX and non-ATEX applications
- Plug-and-play installation with Eilersen digital load cells
- Advanced digital filters (configurable)
- A ”Digital Junction Box” that can be mounted near the load cells or in a central panel
- Small Form Factor
- Setup via dip switches
- For ATEX when supplied by power supply type 4051A
- Application software can be made by request
- The power supply 4051A and module type 4X50A must be installed outside the hazardous zone
Options:
- Prepared for panel mounting on DIN rail
- Mounted in stainless steel housing
- Customized application software
- OEM version
EtherNet/IP Interface Module 2050
EtherNet interface module. For interfacing up to eight digital non-ATEX load cells via EtherNet/IP.
Type: 2050
Interface: EtherNet/IP
Special features:
- EtherNet/IP communication module for interfacing Eilersen digital load cells to PCs, PLCs and other equipment
- Made in Denmark
- The module can be used for up to 8 digital load cells and transmits the weight and status for each individual load cell
- The module offers plug-and-play installation with Eilersen pre-calibrated digital load cells
- The module is supplied with an EDS file for easy installation
- Application software can be made by request
Options:
- Customized application software
- Prepared for panel mounting on DIN rail
- Mounted in stainless steel housing
- OEM version